The calculation of the heat of the warm floor is carried out taking into account the heat loss through the enclosing structures and the useful area of ​​the rooms. Calculation errors affect the operation of the system, increase energy consumption and housekeeping costs. Errors are due to the use of aggregated indicators. The efficiency of insulation and tightness of structures (foundation, load-bearing walls, ceilings, roofing, double-glazed windows, entrance doors) guarantees an economical consumption of energy resources in the system water floor heating.

A scrupulous calculation of the underfloor heating project increases the energy efficiency of the entire heating system and reduces the cost of its maintenance

A scrupulous calculation of the underfloor heating project increases the energy efficiency of the entire heating system and reduces the cost of its maintenance

Appointment and calculation of heat underfloor heating

The low-pressure heating circuit can optimize radiator heating or provide equivalent heating to the home and reduce energy costs.

The heating element and the coolant are design features that distinguish between water and electric underfloor heating. You can calculate the power of an electric underfloor heating using online calculators that are posted on specialized services on the Internet. In this article, we will take a closer look at the purpose and calculation of the power of water-heated floors.

Table 1. Recommended specific power of water floor heating per unit area:

Design features of a residential building Underfloor heating power, W / m2 (min / max)
Additional (comfort) heating
Year of construction of the building - until 1996, climatic region - European part of Russia 80/120
Year of construction of the building - after 1996 (improved external insulation, basement and roof insulation, double-glazed windows), climatic region - the European part of Russia 50/80
In rooms with wooden floors (subfloor and subfloor) 80/80
Loggias (balconies) with double glazing and insulation 140/180
Main heating of the house
Kitchens, living rooms on the first and second floor (at least 3/4 of the heated area) 150/∞
Heat dissipation of a heating system using radiators and underfloor heating

Heat dissipation of a heating system using radiators and underfloor heating

Heat Q (W), which produces 1 square meter of low-pressure water circuit, is the total flux of radiant (≈ 4.9 W / m²) and convective (≈ 6.1 W / m²) energy:

Q =

l× (tgender - tOK) + αto× (tgender - tair)] × S, (W), where

αl and αto - radiant and convective energy fluxes, W / m²;

tgender - flooring temperature, ° C;

tOK - temperature of walls and ceiling, ° C;

tair - room temperature, ° C;

S - useful area of ​​the contour, m2.

Scheme 1. Calculation of warm water floor

Scheme 1. Calculation of warm water floor

Explanation of schemes 1 and 2 for calculating a warm floor:

  • 1 - floor slab;
  • 2 - insulation (expanded polystyrene);
  • 3 - screed (ready-made dry mix or cement-sand mortar);
  • 4 - pipe;
  • 5 - self-adhesive compensation tape;
  • 6 - reinforcing cage or mesh (fastening);
  • 7 - laminate flooring or adhesive layer for tiles;
  • 8 - finishing floor covering;
  • 9 - waterproofing;
  • 10 - wall.
  • a - pipe pitch (0.15 ÷ 0.3 m);
  • b - distance from the bearing wall (0.3 m);
  • c - insulation thickness (0.02 ÷ 0.1 m);
  • f - thickness of the reinforcement mesh (0.04 ÷ 0.1m);
  • d - total thickness of the screed (0.03 ÷ 0.07 m);
  • r, Dy - wall thickness and pipe inner diameter;
  • g - screed thickness above the pipe (0.3 m);
  • k is the thickness of the substrate or layer of tile adhesive (0, 005 ÷ 0.01 m);
  • h is the thickness of the floor covering (0.015 ÷ 0.025 m).
Scheme 2. Screed device in the water floor heating system

Scheme 2. Screed device in the water floor heating system

Calculation of underfloor heating determines the heat consumption of a residential building in accordance with regulatory documents on thermal protection of buildings and construction heat engineering:

Q = (αl + αto) × S × (tgender - tair), (W);

tgender = Q / [(αl + αto) × S] + tair, (° C);

at S = 1m², tgender = Q / (αl + αto) + tair, (° C).

When the room temperature is heated by 1 degree, heat from the floor surface is transferred to the air:

∆t = tgender - tair = 1 ° C;

Q = (αl + αto) × S × ∆t = (4.9 + 6.1) × 1 × 1 = 11 (W).

Arrangement of a screed for a water-heated floor

Arrangement of a screed for a water-heated floor

The ideal conditions under which the heat transfer of the water circuit on one square meter of the heated floor for heating the air in the room by 1 ° C is 11 W / m². The higher the temperature in the room, the faster the room will warm up and the lower the energy consumption of the heat carrier. The underfloor heating system is preferable in order to heat insulated residential houses with permanent residence. Average admissible value of heat loss 65 W / m².

To calculate the heat transfer of a warm floor, there are special programs that can be found on the resources on the network. To clarify the issue, we suggest that you familiarize yourself with the video "Calculation of heat transfer under floor heating".

Heat carrier temperature

The temperature of the heating medium in the circuit depends on the heat load, the laying pitch, the pipe diameter, the thickness of the screed and the material of the floor covering. The minimum temperature values ​​in the circuit are taken for parquet boards and small-piece wood products. Tiled, metlakhskaya, ceramic tiles, porcelain stoneware, marble can withstand the maximum allowed temperature of the heat carrier (55 ° C). Low-pressure heating schemes that are used in practice have an operating range of 45/35 ° C.

Sanitary standards determine the comfortable (26 ° C) and permissible temperature limit for a human foot:

  • 28 ° C in living rooms for permanent residence;
  • 35 ° C along the perimeter of the load-bearing walls of a residential building;
  • 33 ° C for kitchens, baths and sanitary rooms.
According to sanitary standards, the temperature of the coolant in the bathroom should be 33 degrees

According to sanitary standards, the temperature of the coolant in the bathroom should be 33 degrees

Underfloor heating bases

The type of overlap affects the materials and the choice of layer thicknesses above and below the pipe. Underfloor heating is based on cement screeds and flooring systems made of polystyrene or wooden inter-tube boards. The aluminum profile in the rack modules serves as insulating wood from direct contact with the heating element and for fastening pipes.

Related article:

vodyanoj-teplyj-pol-svoimi-rukami-1mDo-it-yourself water floor heating, video and description of the process. Description of the process of installing a water-heated floor. Its advantages and disadvantages, in contrast to other types of floor heating systems. Selection of materials. Video lessons.

Circuit piping on concrete floor slabs arrange a concrete screed in the body. The volume of material and installation calculations of warm floors are determined after preliminary marking of the surface (hydraulic or laser level). The layout plan is carried out on paper (scale 1:50). The accuracy with which the calculation is carried out determines the consumption of material and the speed of work.

In the flat installation of the warm floor, the modular slabs have grooves for laying water floor pipes

In the flat installation of the warm floor, the modular slabs have grooves for laying water floor pipes

The surface cleaned and treated with a polymer primer is leveled in advance, waterproofing is done on the soils and first floors. The walls are glued around the perimeter with a damper tape to a height that will go under the screed (with a small margin). Thermal insulation material with a foil base shields the specific heat flux upward in a given direction. Heat loss through the foil does not exceed 5%.

The reinforcement is laid on top of the insulation, the frame gives rigidity to the screed and allows you to achieve the correct fixation of the step. The pipe loop is laid out, fastened, the loop is tested under pressure and filled with a screed solution.

Warm water floor mounted using special mats

Warm water floor mounted using special mats

Lightweight modular systems are used for wooden structures (subfloor or logs) that do not have the ability to withstand high static loads.

Calculations of pipes for a water-heated floor (length, diameter, pitch and methods of laying and pipes)

The limited length of the low-pressure heating circuit is related to the “closed loop” effect, in which the pressure loss exceeds 20 kPa (0.2 bar). An increase in pump power, in this case not an output - the resistance will increase in proportion to the increase in pressure.

It is better to equip warm water floors in premises where they live permanently, and not use from time to time

It is better to equip warm water floors in premises where they live permanently, and not use from time to time

The estimated length of pipes for a warm floor is determined by the formula:

L = (S / a × 1.1) + 2c, (m), where

L - contour length, m;

S - area, contour, m²;

a - laying step, m;

1.1 - increasing the size of the bending step (margin);

2c - the length of the supply pipes from the collector to the circuit, m.

Important! The usable room area takes into account the contour area with the addition of half the pipe pitch.

The heating circuit is laid at a distance of 0.3 m from the walls. Take into account the open floor area, which transmits a uniform radiation flux. Experts do not recommend installing the heating circuit in the places where furniture is placed. Prolonged static loading can deform pipes.

With a large area of ​​the room, the heating circuit is divided into sectors. The basic zoning rules are the aspect ratio 1/2, heating the area of ​​one sector no more than 30 m² and keeping the same length and diameter for the chains of one collector.

The temperature of the heating medium in the underfloor heating circuit depends on the heat load, the laying pitch, the diameter of the pipes, the thickness of the screed and the material of the floor covering

The temperature of the heating medium in the underfloor heating circuit depends on the heat load, the laying pitch, the diameter of the pipes, the thickness of the screed and the material of the floor covering

Table 2. The ratio of the lengths and diameters of the circuit pipes:

Diameter, mm Pipe material Recommended loop length, m
16 metal-plastic 80 ÷ 100
18 cross-linked polyethylene 80 ÷ 120
20 metal-plastic 120 ÷ 150

 

The diameter and pitch of the pipe layout depends on the heat load, purpose, size and geometry of the room. The heat distribution zone is proportional to the radius of the pipe. The pipe heats a section of the floor on each side of the center of the pipe. Balanced pipe spacing: Dy 16 mm - 0.16 m; 20 mm - 0.2 m; 26 mm - 0.26 m; 32 mm - 0.32 m.

Construction of metal-plastic pipes for a warm water floor

Construction of metal-plastic pipes for a warm water floor

The passport data of the products indicate the maximum throughput of the pipes, on the basis of which the linear pressure change is calculated. The optimal value of the speed of the coolant in the pipes water heating 0.15 ÷ 1 m / s.

Table 3. Dependence of the step on the area and sector load:

Diameter, mm Distance along the axes (pipe spacing), m Optimal load, W / m2 Total (or divided into sections) usable area of ​​the premises, m2
16 0,15 80 ÷ 180 12
20 0,20 50 ÷ 80 16
26 0,25 20
32 0,30 less than 50 24

 

Pipe-laying options: simple, corner or double loops (snakes), spirals (snails). For narrow corridors and rooms of irregular shape, snake laying is used. Large areas are divided into sectors. Combined laying is allowed: in the edge zone, the pipe is laid out with a snake, in the main part - with a snail.

Options for laying pipes for a water-heated floor

Options for laying pipes for a water-heated floor

Around the perimeter, closer to the outer wall and near the window openings, the contour feed passes. The laying spacing in the edge zones may be less than the distance between pipes in the central part of the room. Connecting the reinforcements of the edge zone is necessary to increase the power of the heat flow.

Important! A 90 ° bend of pipes in a spiral scheme for connecting a water-heated floor reduces hydraulic resistance less, in comparison with laying in loops (snake).

In the calculations of pipes for a water-heated floor, diameters of 16, 20, 26, 32 mm are used.

Laying water floor heating pipes in a spiral pattern reduces hydraulic resistance

Laying water floor heating pipes in a spiral pattern reduces hydraulic resistance

For systems of warm water floors, corrugated, stainless steel, copper, metal-plastic, cross-linked polyethylene pipelines are used. Corrugation of the pipe for underfloor heating has become relatively recent in order to facilitate the installation of the structure and reduce the cost of turning increases in length.

Polypropylene piping has a large bending radius, so it is rarely used in underfloor heating systems.

Corrugated stainless steel pipe for water floor heating

Corrugated stainless steel pipe for water floor heating

Floor coverings

Types of finishing flooring for warm floors: filling surface, linoleum, laminate or parquet, tiles, ceramic and metlakh tiles, marble, granite, basalt and porcelain stoneware.

The constant humidity in the room is contraindicated for wooden flooring, therefore it is not used in bathrooms with warm floors.

Table 4. Thermal conductivity of floor coverings:

Material type Layer thickness δ, m Density γ, kg / m³ Thermal conductivity coefficient λ, W / (m ° ∁)
Insulated linoleum 0,007 1600 0,29
Tiles are tiled, metlakh, ceramic 0,015 1800 ÷ 2400 1,05
Laminate 0,008 850 0,1
Parquet board 0,015 ÷ 0,025 680 0,15
Insulation (ursa) 0,18 200 0,041
Cement-sand screed 0,02 1800 0,76
Reinforced concrete slab 0,2 2500 1,92

 

Installation of a water-heated floor in a concrete screed with a final coating of tiles

Water device warm floor in a concrete screed with a final coating of tiles

Pumping equipment for underfloor heating calculations

Reducing the temperature of the coolant allows you to achieve efficient operation of the circulation pumps.

The underfloor heating circuit is horizontal and covers a large area. The force that the circulating pump imparts to the flow is spent on overcoming linear and local resistances. The calculation of the pump for underfloor heating depends on the diameter, roughness of the pipe, fittings and the length of the circuit.

Connection diagram of a heating system with a warm water floor

Connection diagram of a heating system with a warm water floor

The main calculation parameter is the pump performance in the low-pressure circuit:

H = (P × L + ΣK) / 1000, (m), where

H is the head of the circulation pump, m;

P - hydraulic loss per running meter of length (passport data from the manufacturer), pascal / meter;

L is the maximum length of pipes in the circuit, m;

K is the power factor for local resistances.

K = K1 + K2 + K3where

K1 - resistance on adapters and tees, connections (1,2);

K2 is the resistance on the valves (1,2);

K3 - resistance at the mixing unit in the heating system (1.3).

Pressure characteristic of the circulation pump

Pressure characteristic of the circulation pump

The degree of performance possessed by the circulation pump is determined by the formula:

G = Q / (1.16 × ∆t), (m³ / hour), where

Q is the heat load of the heating circuit (W);

1.16 - specific heat capacity of water (Wh / kgC);

∆t - heat removal in the system (for low-pressure circuits 5 ÷ 10 ° С).

Manifold cabinet with connected floor heating system

Manifold cabinet with connected floor heating system

Table 5. Dependence of the power of the unit on the area of ​​the heated premises (for hydraulic calculation of the warm floor):

Floor area, m2 Capacity of the circulation pump for underfloor heating, m³ / h
80 ÷ 120 1,5
120 ÷ 160 2,0
160 ÷ 200 2,5
200 ÷ 240 3,0
240 ÷ 280 4,0

 

Helpful advice! The power of the unit consists of the sum of the costs of all circuits. In case of abnormal cold weather, it is necessary to provide a pump capacity reserve of 15 ÷ 20%.

An example of a wiring diagram for a warm water floor by sector

An example of a wiring diagram for a warm water floor by sector

Calculation of the cost of underfloor heating

Gas boiler and the floor hydraulic circuit connects the manifold. A uniform flow of the heat carrier is provided by automatic regulation, using balancing and thermostatic valves. The non-return valve protects the pump-mixing unit.

Table 6. Elements of a complete set of warm floor:

Item name Size and unit Unit price (RUB)
Waterproofing roll (1.5 × 50 m) from 2000
Damper tape 25 m from 500
Shielding thermal insulation (expanded polystyrene) 1100 × 800 × 38 mm 769
Trumpet 16 ÷ 20 mm 50 ÷ 80
Concrete screed:
cement
dry mixes
50 Kg
25 Kg
125
200
Collector group assembled 2 outputs 4600
Pump and mixing unit: thermostatic head, balancing and thermostatic valves, circulation pump set from 20,000

 

The total cost of underfloor heating is determined by the area of ​​the room, the equipment, the quality of the material and the method of work. Batch formation of a warm floor provides compatibility of elements and effective heating in temperature ranges. Factory equipment reduces the cost of materials by 1.5-2 times.

Elements of a combined heating system

Elements of a combined heating system

The owner of the house can make a calculation of water-heated floors, install the system with his own hands, if he has a sufficient stock of knowledge in heat engineering, hydraulics, materials science and experience in performing plumbing work. The mass of positive examples from life is inspiring. However, everyone should carry "their own portfolio", their own home is not a springboard for experiments.